Journal article
Effect of Pulse Rate and Polarity on the Sensitivity of Auditory Brainstem and Cochlear Implant Users to Electrical Stimulation
RP Carlyon, JM Deeks, CM McKay
JARO Journal of the Association for Research in Otolaryngology | Published : 2015
Open access
Abstract
To further understand the response of the human brainstem to electrical stimulation, a series of experiments compared the effect of pulse rate and polarity on detection thresholds between auditory brainstem implant (ABI) and cochlear implant (CI) patients. Experiment 1 showed that for 400-ms pulse trains, ABI users’ thresholds dropped by about 2 dB as pulse rate was increased from 71 to 500 pps, but only by an average of 0.6 dB as rate was increased further to 3500 pps. This latter decrease was much smaller than the 7.7-dB observed for CI users. A similar result was obtained for pulse trains with a 40-ms duration. Furthermore, experiment 2 showed that the threshold difference between 500- an..
View full abstractGrants
Awarded by Medical Research Council