Journal article

Bayesian validation of the indirect immunofluorescence assay and its superiority to the enzyme-linked immunosorbent assay and the complement fixation test for detecting antibodies against Coxiella burnetii in goat serum

M Muleme, J Stenos, G Vincent, A Campbell, S Graves, S Warner, JM Devlin, C Nguyen, MA Stevenson, CR Wilks, SM Firestone

Clinical and Vaccine Immunology | Published : 2016

Abstract

Although many studies have reported the indirect immunofluorescence assay (IFA) to be more sensitive in detection of antibodies to Coxiella burnetii than the complement fixation test (CFT), the diagnostic sensitivity (DSe) and diagnostic specificity (DSp) of the assay have not been previously established for use in ruminants. This study aimed to validate the IFA by describing the optimization, selection of cutoff titers, repeatability, and reliability as well as the DSe and DSp of the assay. Bayesian latent class analysis was used to estimate diagnostic specifications in comparison with the CFT and the enzyme-linked immunosorbent assay (ELISA). The optimal cutoff dilution for screening for I..