Journal article
Controlling the frequency-temperature sensitivity of a cryogenic sapphire maser frequency standard by manipulating Fe3 spins in the sapphire lattice
K Benmessai, DL Creedon, JM Le Floch, ME Tobar, M Mrad, PY Bourgeois, Y Kersalé, V Giordano
Physical Review B Condensed Matter and Materials Physics | AMER PHYSICAL SOC | Published : 2012
Abstract
To create a stable signal from a cryogenic sapphire maser frequency standard, the frequency-temperature dependence of the supporting whispering gallery mode must be annulled. We report the ability to control this dependence by manipulating the paramagnetic susceptibility of Fe3 + ions in the sapphire lattice. We show that the maser signal depends on other whispering gallery modes tuned to the pump signal near 31 GHz, and the annulment point can be controlled to exist between 5 and 10 K, depending on the Fe3 + ion concentration and the frequency of the pump. This level of control has not been achieved previously and will allow improvements in the stability of such devices. © 2012 American Phy..
View full abstractGrants
Awarded by Australian Research Council
Funding Acknowledgements
The authors wish to thank the Australian Research Council for supporting this work under Grants No. FL0992016, No. CE11E0082, and No. DP1092690, and ISL Grant No. FR100013.