Journal article

Inherent limitations and alternative to conventional equivalent strut models for masonry infill-frames

A Mohyeddin, S Dorji, EF Gad, HM Goldsworthy

Engineering Structures | ELSEVIER SCI LTD | Published : 2017

Abstract

Past studies have confirmed that the behaviour of an infill-frame can be remarkably different from that of a bare frame. This becomes specifically critical when the structure is under lateral loads such as wind and earthquake. This paper looks into the fundamentals of the most commonly used analytical method for the analysis of such structures, i.e. equivalent strut modelling. It is shown that even though several equivalent strut models have been proposed since the 1950s, none can be considered as a suitable generic tool to represent the behaviour of all infill-frame structures. It is further demonstrated that not only the total width of strut(s), but also the number and location of strut(s)..

View full abstract

University of Melbourne Researchers