Journal article
Comparison of optimised planar scintigraphy with SPECT thallium, exercise ECG and angiography in the detection of coronary artery disease
PJ Roach, PS Hansen, AM Scott, RA Cooper, R Hoschl, JC Wiseman, A Bernar, AC Edwards
Australian and New Zealand Journal of Medicine | ADIS PRESS AUSTRALASIA P/L | Published : 1996
Abstract
Background: Thallium SPECT has been shown to be more sensitive than planar imaging in the detection of coronary heart disease (CAD) in a number of reported series. Early (70% stenosis) CAD, seven patients with borderline stenoses (50-69%) and in 18 patients with no significant CAD. Results: The sensitivity of planar imaging was 66% which was higher than exercise ECG 54% (ns) but significantly lower than SPECT 86% (p<0.005). The specificity of planar thallium scintigraphy was 100% which was higher than SPECT (83%) and significantly higher than exercise ECG 72% (p<0.05). SPECT had a significantly higher sensitivity for LAD and single vessel disease than planar imaging and this was unrelated to..