Journal article
Estimation of anisotropic permeability in trabecular bone based on microCT imaging and pore-scale fluid dynamics simulations
C Daish, R Blanchard, K Gulati, D Losic, D Findlay, DJE Harvie, P Pivonka
Bone Reports | Published : 2017
Abstract
In this paper, a comprehensive framework is proposed to estimate the anisotropic permeability matrix in trabecular bone specimens based on micro-computed tomography (microCT) imaging combined with pore-scale fluid dynamics simulations. Two essential steps in the proposed methodology are the selection of (i) a representative volume element (RVE) for calculation of trabecular bone permeability and (ii) a converged mesh for accurate calculation of pore fluid flow properties. Accurate estimates of trabecular bone porosities are obtained using a microCT image resolution of approximately 10 μm. We show that a trabecular bone RVE in the order of 2 × 2 × 2 mm3 is most suitable. Mesh convergence stud..
View full abstractGrants
Awarded by Australian Research Council