Journal article
Plasma-Lyte 148 vs. Hartmann’s solution for cardiopulmonary bypass pump prime: a prospective double-blind randomized trial
L Weinberg, E Chiam, J Hooper, F Liskaser, AK Hawkins, D Massie, A Ellis, CO Tan, D Story, R Bellomo
Perfusion United Kingdom | SAGE PUBLICATIONS LTD | Published : 2018
Abstract
Background: The mechanisms of acid-base changes during cardiopulmonary bypass (CPB) remain unclear. We tested the hypothesis that, when used as CPB pump prime solutions, Plasma-Lyte 148 (PL) and Hartmann’s solution (HS) have differential mechanisms of action in their contribution to acid-base changes. Methods: We performed a prospective, double-blind, randomized trial in adult patients undergoing elective cardiac surgery with CPB. Participants received a CPB prime solution of 2000 mL, with either PL or HS. The primary endpoint was the standard base excess (SBE) value measured at 60 minutes after full CPB flows (SBE60min). Secondary outcomes included changes in SBE, pH, chloride, sodium, lact..
View full abstract