Journal article
Accuracy of Different Implant Impression Techniques: Evaluation of New Tray Design Concept
DY Liu, FN Cader, J Abduo, J Palamara
Journal of Prosthodontics | WILEY | Published : 2019
DOI: 10.1111/jopr.12733
Abstract
Purpose: To evaluate implant impression accuracy with a new tray design concept in comparison to nonsplinted and splinted impression techniques for a 2-implant situation. Materials and Methods: A reference bar titanium framework was fabricated to fit on 2 parallel implants. The framework was used to generate a resin master model with 2 implants that fit precisely against the framework. Three impression techniques were evaluated: (1) nonsplinted, (2) splinted, and (3) nonsplinted with modified tray impressions. All the trays were fabricated from light-cured acrylic resin material with openings that corresponded to the implant impression copings. Ten impressions were taken for each technique u..
View full abstractGrants
Funding Acknowledgements