Abstract

OBJECTIVE: To evaluate stiffness and bone-pin interface stress for a transcortical tapered-sleeve pin (TSP) that incorporates bilateral tapered sleeves over a transcortical pin. SAMPLE POPULATION: 14 third metacarpal bones (MCIII) collected from adult horses of various breeds. PROCEDURE: Each MCIII was cut in half to provide 2 test specimens. Pins (conventional and TSP) of 3 diameters (6.35, 7.94, and 9.50 mm) were inserted in specimens (3 specimens for each diameter and each type of pin). The test fixture simulated a typical sidebar-span skeletal fixation device for horses. Single cycle load-deflection tests were performed. Cyclic fatigue tests of TSP were performed to evaluate fatigue char..