Journal article

Non-Invasive Estimation of Cardiac Index in Healthy Volunteers

CT Eyeington, P Ancona, L Cioccari, N Luethi, NJ Glassford, GM Eastwood, HK Proimos, F Franceschi, MJ Chan, D Jones, R Bellomo

Anaesthesia and Intensive Care | SAGE PUBLICATIONS LTD | Published : 2018

Abstract

The primary objective was to non-invasively measure the cardiac index (CI) and associated haemodynamic parameters of healthy volunteers and their changes with age. This was a single centre, prospective, observational study of healthy volunteers aged between 20 and 59 years, using the ClearSight™ (Edwards Life Sciences, Irvine, CA, USA) device. We recorded 514 observations in 97 participants. The mean CI was 3.5 l/min/m2 (95% confidence interval [95% CI] 3.4 to 3.7 l/min/m2). The mean stroke volume index (SVI) was 47 ml/m2 (95% CI 45 to 49 ml/m2) and the mean systemic vascular resistance index was 2,242 dyne·s/cm5/m2 (95% CI 2,124 to 2,365 dyne·s/cm5/m2). There was an inverse linear relations..

View full abstract

University of Melbourne Researchers