Journal article
Development of a consensus document to improve multireader concordance and accuracy of aortic regurgitation severity grading by echocardiography versus cardiac magnetic resonance imaging
A Dahiya, M Bolen, RA Grimm, LL Rodriguez, JD Thomas, TH Marwick
American Journal of Cardiology | EXCERPTA MEDICA INC-ELSEVIER SCIENCE INC | Published : 2012
Abstract
Current guidelines recommend a multiparametric echocardiographic assessment of aortic regurgitation (AR). However, the absence of a hierarchical weighting of discordant parameters could cause interobserver variability. In the present study, we sought to define and improve the interobserver variability of AR assessment. Seventeen level 3 readers graded 20 randomly selected patients with AR. The readers also provided a usefulness score for each parameter, depending on its influence on their decision of the AR severity grade. A consensus strategy was subsequently formulated and validated against cardiac magnetic resonance imaging in a separate group of 80 patients. The readers were updated with..
View full abstractGrants
Awarded by National Center for Research Resources