Journal article
Effect of modified tray design on accuracy of different impression techniques for parallel and divergent implants
L Dang, M Woliansky, J Palamara, J Abduo
Journal of Oral Science | NIHON UNIV, SCHOOL DENTISTRY | Published : 2020
Open access
Abstract
This study evaluated the effect of a modified tray design on the accuracy of implant impressions in comparison with the non-splinted and splinted impression techniques. Two titanium frameworks were produced to fit two parallel implants and two divergent implants with a 15o angle. According to the frameworks employed, two acrylic resin master models were fabricated. For each model, 10 impressions were taken with every technique. The maximum framework principal strain was calculated for every generated cast. For the parallel implant model, the strains of the nonsplinted (118.4 με), splinted (89.0 με), and modified tray design impression (49.4 με) techniques were statistically similar (P = 0.16..
View full abstractGrants
Funding Acknowledgements
The authors would like to acknowledge the technical support of Mr Attila Gergely in developing the master models and the custom trays. This study was supported by Melbourne Dental School Research Higher Degree Funding.