Journal article
Penumbral mismatch is underestimated using standard volumetric methods and this is exacerbated with time
H Ma, JA Zavala, H Teoh, L Churilov, M Gunawan, J Ly, P Wright, T Phan, S Arakawa, SM Davis, GA Donnan
Journal of Neurology Neurosurgery and Psychiatry | BMJ PUBLISHING GROUP | Published : 2009
Abstract
Background and aim: The mismatch between perfusion weighted images (PWI) and diffusion weighted images (DWI) using MR is increasingly being applied in patient selection for therapeutic trials. Two approaches to the calculation of the mismatch volume exist - the commonly used volumetric and the more precise co-registration method, the latter of which considers lesion topography. That there are differences in the mismatch volume analysed by each method and that these are time dependent was hypothesised. Methods: Patients within 48 h of ischaemic stroke onset had baseline MR PWI/DWI mismatch and T2 outcome volumes at 3 months. Volumetric mismatch volume was defined as PWI minus DWI lesion. Co-r..
View full abstractGrants
Funding Acknowledgements
National Health and Medical Research Council of Australia and Pfizer CVL.