Observation of picometer vertical emittance with a vertical undulator
KP Wootton, MJ Boland, R Dowd, YRE Tan, BCC Cowie, Y Papaphilippou, GN Taylor, RP Rassool
Physical Review Letters | AMER PHYSICAL SOC | Published : 2012
Abstract
Using a vertical undulator, picometer vertical electron beam emittances have been observed at the Australian Synchrotron storage ring. An APPLE-II type undulator was phased to produce a horizontal magnetic field, which creates a synchrotron radiation field that is very sensitive to the vertical electron beam emittance. The measured ratios of undulator spectral peak heights are evaluated by fitting to simulations of the apparatus. With this apparatus immediately available at most existing electron and positron storage rings, we find this to be an appropriate and novel vertical emittance diagnostic. © 2012 American Physical Society.