Journal article

Cost Minimisation Analysis: Kilovoltage Imaging with Automated Repositioning Versus Electronic Portal Imaging in Image-guided Radiotherapy for Prostate Cancer

S Gill, S Younie, A Rolfo, J Thomas, S Siva, C Fox, T Kron, D Phillips, KH Tai, F Foroudi

Clinical Oncology | ELSEVIER SCIENCE LONDON | Published : 2012

Abstract

Aims: To compare the treatment time and cost of prostate cancer fiducial marker image-guided radiotherapy (IGRT) using orthogonal kilovoltage imaging (KVI) and automated couch shifts and orthogonal electronic portal imaging (EPI) and manual couch shifts. Materials and methods: IGRT treatment delivery times were recorded automatically on either unit. Costing was calculated from real costs derived from the implementation of a new radiotherapy centre. To derive cost per minute for EPI and KVI units the total annual setting up and running costs were divided by the total annual working time. The cost per IGRT fraction was calculated by multiplying the cost per minute by the duration of treatment...