Journal article

The upgraded photon tagging facility at the MAX IV Laboratory

JO Adler, M Boland, J Brudvik, K Fissum, K Hansen, L Isaksson, P Lilja, LJ Lindgren, M Lundin, B Nilsson, D Pugachov, A Sandell, B Schroder, V Avdeichikov, P Golubev, B Jakobsson, JRM Annand, K Livingston, R Igarashi, L Myers Show all

Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment | Published : 2013

Abstract

A description is given of the upgraded photon tagging facility at the MAX IV Laboratory. Two magnetic spectrometers are used to momentum analyze post-bremsstrahlung electrons. The tagged photon range extends from 10 to 180 MeV with an energy resolution of about 300 keV. The system has been operated at rates up to 4×106 photons s-1 MeV -1. Different diagnostic tools are described as well as the experimental program. © 2013 Elsevier B.V.

University of Melbourne Researchers

Grants

Awarded by Sixth Framework Programme


Funding Acknowledgements

The authors acknowledge the outstanding support of the MAX-lab staff. We acknowledge the support of the Swedish Research Council, the Knut and Alice Wallenberg Foundation, the Crafoord Foundation and the Royal Physiographic Society in Lund. We also acknowledge the support by the European Community-Research Infrastructure Action under the FP6 "Structuring the European Research Area" Programme (through the Integrated Infrastructure Initiative "HadronPhysic").