Journal article
Quality properties of pre- and post-rigor beef muscle after interventions with high frequency ultrasound
AL Sikes, R Mawson, J Stark, R Warner
Ultrasonics Sonochemistry | Published : 2014
Abstract
The delivery of a consistent quality product to the consumer is vitally important for the food industry. The aim of this study was to investigate the potential for using high frequency ultrasound applied to pre- and post-rigor beef muscle on the metabolism and subsequent quality. High frequency ultrasound (600 kHz at 48 kPa and 65 kPa acoustic pressure) applied to post-rigor beef striploin steaks resulted in no significant effect on the texture (peak force value) of cooked steaks as measured by a Tenderometer. There was no added benefit of ultrasound treatment above that of the normal ageing process after ageing of the steaks for 7 days at 4 °C. Ultrasound treatment of post-rigor beef steaks..
View full abstractGrants
Funding Acknowledgements
The authors would like to thank Ms Jenny Favaro for expert technical assistance and acknowledge funding from the Australian Meat Processor Corporation, Meat and Livestock Australia and CSIRO for this research.